Menu

Commercial HVAC Repair Services for Plano Businesses

When your commercial HVAC system fails in Plano, TX, every minute counts. Business operations depend on maintaining comfortable temperatures for employees, customers, and sensitive equipment. At Bill Joplin’s Air Conditioning & Heating, we understand that commercial HVAC repair requires specialized expertise beyond residential service. Since our founding in 1978, we’ve developed comprehensive repair capabilities specifically designed to address the complex demands of commercial heating and cooling systems throughout Plano and neighboring communities including McKinney, Allen, Fairview, Prosper, and Melissa.

Commercial HVAC systems operate under significantly different parameters than residential units. These systems typically run longer hours, handle larger volumes of air, and must maintain precise temperature and humidity levels across expansive spaces. Our technicians receive ongoing training on the latest commercial equipment, including rooftop units, split systems, packaged units, and variable refrigerant flow systems commonly found in Plano’s office buildings, retail spaces, restaurants, and industrial facilities.

Common Commercial HVAC Problems We Repair

Commercial HVAC systems in Plano face unique challenges due to our extreme temperature variations and high humidity levels. During summer months when temperatures regularly exceed 100 degrees Fahrenheit, commercial cooling systems work overtime to maintain comfortable indoor environments. This constant operation can lead to accelerated wear on components like compressors, fan motors, and evaporator coils. We frequently repair refrigerant leaks that develop in commercial systems due to vibration from continuous operation and exposure to harsh rooftop conditions.

Indoor air quality issues represent another significant concern for commercial properties. Poor ventilation, clogged filters, and malfunctioning economizers can create uncomfortable and potentially unhealthy environments for building occupants. We diagnose and repair ventilation problems, ensuring proper fresh air intake while maintaining energy efficiency. Our repair services also address humidity control issues that can lead to mold growth, particularly important for Plano businesses storing inventory or operating sensitive electronic equipment.

Emergency Response and Diagnostic Procedures

When we receive an emergency repair call from a Plano business, our response protocol prioritizes rapid diagnosis and resolution. Our service vehicles carry extensive inventories of commercial-grade parts and specialized diagnostic equipment. Upon arrival, we perform systematic evaluations starting with thermostat calibration and control system verification. We check electrical connections, measure amperage draws on motors and compressors, and analyze refrigerant pressures to identify both immediate failures and potential future problems.

Advanced diagnostic tools allow us to detect issues invisible to standard inspection methods. Thermal imaging cameras reveal hot spots in electrical panels and motors before complete failure occurs. Digital manifold gauges provide precise refrigerant charge measurements and superheat calculations essential for optimal system performance. We also utilize airflow meters to verify proper ventilation rates required by commercial building codes and indoor air quality standards.

Preventive Maintenance and Repair Strategies

Regular maintenance significantly reduces the frequency and severity of commercial HVAC repairs. We develop customized maintenance schedules based on equipment type, usage patterns, and manufacturer specifications. Our preventive maintenance services include:

  • Comprehensive coil cleaning: removing dirt and debris that reduces heat transfer efficiency and increases energy consumption
  • Belt inspection and adjustment: preventing unexpected failures that can shut down entire ventilation systems
  • Refrigerant level optimization: ensuring proper charge levels to maximize cooling capacity and minimize compressor strain
  • Control system calibration: verifying accurate temperature sensing and proper staging of multiple units
  • Drain line cleaning: preventing water damage from clogged condensate removal systems

Energy Efficiency and Cost Considerations

Commercial HVAC systems represent substantial operating expenses for Plano businesses, often accounting for 40 to 50 percent of total energy consumption. Our repair services focus not only on restoring functionality but also on optimizing efficiency. We identify and correct issues that increase energy usage, such as dirty coils reducing heat transfer, worn bearings causing motors to work harder, and improperly calibrated controls causing unnecessary cycling.

Variable frequency drives offer significant energy savings for commercial systems by adjusting motor speeds based on actual cooling demands. When repairing older systems, we often recommend retrofitting these devices to reduce energy consumption by 20 to 30 percent. Similarly, programmable thermostats and building automation systems allow precise temperature control during occupied and unoccupied periods, reducing unnecessary operation while maintaining comfort when needed.

Specialized Equipment and Technical Expertise

Commercial HVAC repair demands specialized knowledge of complex equipment configurations. Rooftop units common on Plano commercial buildings require expertise in economizer controls, exhaust fans, and makeup air systems. These components work together to maintain proper building pressurization while maximizing free cooling opportunities during mild weather conditions. Our technicians understand the intricate balance required between energy recovery ventilators, demand-controlled ventilation systems, and traditional mechanical cooling.

Multi-zone systems present additional repair challenges, requiring careful diagnosis of damper operations, zone control panels, and bypass configurations. We service variable air volume systems that automatically adjust airflow based on zone demands, requiring precise calibration of terminal units and static pressure controls. Heat pump systems, increasingly popular in commercial applications, require specialized knowledge of reversing valves, defrost controls, and auxiliary heat staging that differs significantly from traditional cooling-only equipment.

Industry Compliance and Safety Standards

Commercial HVAC repair must comply with numerous regulations and safety standards. We maintain current certifications for handling refrigerants according to EPA Section 608 requirements. Our technicians follow OSHA safety protocols when working on rooftops and around electrical equipment. We ensure all repairs meet local building codes and maintain proper documentation for inspection purposes.

Indoor air quality regulations require commercial buildings to maintain specific ventilation rates based on occupancy types and densities. Our repairs ensure systems meet ASHRAE Standard 62.1 requirements for acceptable indoor air quality. We also address Title 24 energy efficiency standards when applicable, ensuring repaired systems maintain required efficiency levels.

Bill Joplin’s Air Conditioning & Heating has established itself as a leading residential HVAC contractor providing heating and cooling services to McKinney, TX, and the surrounding communities, and our commercial division brings that same commitment to excellence to business customers throughout Plano. We understand that commercial HVAC failures impact productivity, revenue, and customer satisfaction. Our rapid response times, comprehensive repair capabilities, and focus on long-term reliability help minimize disruptions to business operations while controlling repair costs through efficient diagnosis and quality workmanship that prevents recurring problems.

Commercial HVAC Repair in Plano, TX

Commercial HVAC Repair in Plano, TX

Commercial HVAC Repair ∴ Plano, TX

Testimonials
Collin County Loves Us
I was satisfied with the team that came out to change my evaporator coil! Mr Andrew and Mr. David were phenomenal. They were an effective team, providing us with their progress trying tokeep us informed. The job wasn’t easy and...
Rudy H.
Bill Joplin’s installed the A/C systems when I built my house almost 30 years ago and I’ve been using them for preventative maintenance and repair ever since. When it was time to replace my worn out systems, I never considered...
Patrick M
Had two HVAC companies look at my non working outside unit. Both said I had a leak but from different spots. Both said I needed a new unit. I then called Joplin’s and they pinpointed the leak (at a totally...
Bobby R.
Bill Joplin is The Best, have used them since ‘04 at 4 different homes. Others may be cheaper but so is their product and service. The actually put a total new system in current home less than other quotes and...
Bill B.
Joplin’s has always taken great care of us for over 20 years. Today was fantastic as our AC went out over Father’s Day weekend. They came to our rescue within two hours of our call and solved our problem in...
Jennifer S.
Had an outage on Labor Day in 105 degree heat in North Texas. Michael from Joplin’s was there in 1 hour and got our unit working again. Analyzed the problem and noticed it was a bad capacitor, and didn’t try...
Chad G.
Learn From The Experts
Latest Articles & Education

Plano, TX